Japanese download page |
Optical software, free download. Simple Software-restriction Policy A software policy makes a powerful addition to Microsoft Windows' malware protection. Optical Design Software for optical systems comprised of light sources, lenses, apertures, prisms, imagers. The optical system to analyze is defined in a normal Zemax lens file. I recommend you to use The original SYNOPSYS™ lens design program which is similar to the softwares you mentioned above, but it has its special and powerful features to make it unique, such as PSD III Algorithm, Dsearch&Zsearch.
Optical Design File Conversion OpTaliX offers comprehensive import and export routines to convert lens prescriptions from other optical design programs such as Code V, Oslo, ZEMAX, ASAP, Atmos, Modas Accos, Sigma2000 and WinLens. Conversion can be done in both ways, that is, from other programs (import) or to other programs (export). Harness the power of Zemax optics software. By harnessing the power of OpticStudio®, OpticsBuilder™, and OpticsViewer™, optical, mechanical, and manufacturing engineers can speak the same language across the optical product development process. Optical design and manufacturability eguides. Increase your optics software knowledge with our design software guides. When you are looking to learn more about designing for manufacturing or optics best practices, our eGuides touch on a large span of tools and highlight the.
Current Versions:
Filename | Date | Size | Description |
OpTaliX-Pro 32/64 bit V10.60, UPDATE Requires purple Sentinel/HASP key. MD5-Checksum: 77255501D2CD684B34F9458A14759E5A optalix_pro_update_1060.exe | 03. Oct. 2020 | 62.11 MB | OpTaliX-Pro update for 32-bit and 64-bit single- and multi-processor versions. Requires a full installation and a valid upgrade license before this upgrade can be installed. See also the version history for the latest changes respectively improvements. |
OpTaliX-Pro NET 32/64 bit V10.60, UPDATE Requires red Sentinel/HASP network key. MD5-Checksum: 36090BF11FD00A380898F8427EC9F4AD optalix_pro_update_NET_1060.exe | 03. Oct. 2020 | 62.11 MB | OpTaliX-Pro update for 32-bit and 64-bit single- and multi-processor versions. Requires a full installation and a valid upgrade license before this upgrade can be installed. See also the version history for the latest changes respectively improvements. |
OpTaliX-LT 10.50 (Free download, 30 days trial) Purchase a permanent license of OpTaliX-LT MD5-Checksum: B3FC2E7B6667816475F16A0AD020D08E optalix_lt_setup_1050.exe | 07. Aug. 2020 | 28.81 MB | OpTaliX-LT is a functionally reduced version of OpTaliX-PRO and focusses on geometrical analyses only. OpTaliX-LT is shareware. You may use it 30 days for free. After this period you should register OpTaliX-LT. OpTaliX-LT runs on Windows versions XP/Vista/7/8/10, both 32-bit and 64-bit operating systems. The latest changes and improvements are summarized in the version history. |
Handbook of Optical Systems. Optical Design Files | Jan. 2009 | 406 KB | All optical design files presented in the 'Handbook of Optical Designs', Vol. 4, from Wiley in the OpTaliX format. Download OpTaliX-LT to open, view and analyze the files, or eventually convert the designs to other formats (Code V, Zemx, Oslo, ASAP). Note: Make sure to check the option 'recurse folders' when extracting the archive. |
Obsolete Versions:
Zemax Optical Studio
Filename | Date | Size | Description |
OpTaliX-Pro-32bit V7.98, update For Hardlock key (blue) only Requires an existing 7.24 installation MD5-Checksum: A748BC3F56BE004F491CB4B29F960A9C optalix_pro_update_798_hardlock.exe | 27.Jan. 2013 | 25.58 MB | OpTaliX-Pro update for users with Hardlock key (blue). Note that support of this version has expired. This version (7.98) is the last version available for this type of hardware key (Hardlock). Users with a valid upgrade license are eligible to upgrade to the most recent version (9.70) at no charge. |
OpTaliX-Pro Server 7.64, update Requires an existing 7.24 installation Requires Hardlock server hardware key MD5-Checksum: 4171006D48140F0C9DC32C0ACFB16700 optalix_pro_upd_serv_764.exe | 22.May 2012 | 26.13 MB | This is the version 7.64 update for OpTaliX-Pro-Server. It requires an existing installation and can only be applied if version 7.24 (server) or higher is already installed. To run this version you need a server hardware key (aka 'dongle'). Please download PDF manuals separately (see below). See also the version history for the latest changes respectively improvements. |
Manuals and Drivers:
Filename | Date | Size | Description |
Reference Manual 10.50 | Aug. 2020 | 6.08 MB | PDF reference manual with numerous internal hyperlinks for easier navigation. It explains all commands available in OpTaliX-LT, OpTaliX-PRO and OpTaliX-EDU. Copy the file into the directory where OpTaliX is installed. |
Tutorial 6.50 | 11.June 2006 | 1.54 MB | Preliminary version of the OpTaliX tutorial. It is not complete but will be constantly extended. As for the reference manual, the tutorial is a PDF file with numerous internal hyperlinks for easier navigation. Copy the file into the directory where OpTaliX is installed. |
Handbook of Optical Systems Vol. 4, Design Files | Jan-2009 | 0.41 MB | All design files presented in the 'Handbook of Optical Deigns', Vol. 4, from Wiley in the OpTaliX format. Download OpTaliX-LT to convert the designs to other formats (Code V, Zemax, Oslo, ASAP). |
June 2020 | 21.26 MB | Sentinel/HASP driver software for Windows Windows Vista, Win7, Win8, Win10, for both 32-bit and 64-bit systems. It is strongly recommended to upgrade to this driver. |
Minimum hardware requirements:
- Pentium 4, 1GHz,- 3 GByte RAM,
- 200 MByte available on hard disc,
- Windows XP/Vista/Win7/Win8/Win10 operating systems required,
- 1024 x 768 pixel monitor resolution or higher recommended.
Should you experience problems to download, install or run OpTaliX, please contact us at .
OpTaliX offers comprehensive import and export routines to convert lens prescriptions from other optical design programs such as Code V, Oslo, ZEMAX, ASAP, Atmos, Modas Accos, Sigma2000 and WinLens. Conversion can be done in both ways, that is, from other programs (import) or to other programs (export). At present, WinLens files can only be imported.
The import/export capabilities of OpTaliX are comprehensive in a way that also advanced features like decenters, tilts, gradients, gratings, special apertures, etc are recognized and converted.
Note, however, that it is virtually impossible to convert ALL features offered by various optical design programs. Not only that features are implemented in a completely different manner because program philosophies are vastly divergent, the major problem is lack of documetation about the formats how design data are stored. To the extreme, some vendors are trying to obscure format details to the maximum possible extent. Quite often the only rescue out of this problem is by 'reverse engineering'. This is a tedious process. Another problem is that file formats are often changed without prior notice, for example if new features are added. This may lead to the situation that a feature that could be previously converted without problems now eventually leads to inappropriate conversion results. Despite all of these difficulties, OpTaliX attempts to recognize a maximum amount of commands and features stored in external lens design files.
Imported files can be viewed, analyzed and modified in all versions of OpTaliX, including OpTaliX-LT. Go to the download page to obtain your copy of OpTaliX-LT (30 days free, after this period registration is required).
Zemax Software Download
OpTaliX-LT converts the following prescription items to/from Code V, Zemax, Oslo, Atmos, Modas, WinLens, Accos and Sigma PC/2000 :
Zemax Optical Design
Legend: | = fully converted |
NA | = not applicable. This feature is not offered by the designated program. |
blank cells denote features, which are not converted yet, but are on the wish list. |
ACCOS and Sigma2000 are outdated and are no longer commercially available. Therefore, only import facilities will be provided for these programs. This allows you to convert old ACCOS and SIGMA-files to more recent optical design packages. Since the WinLens file format has undergone numerous modifications in the past, export to WinLens will only be offered when there is a stable format and a demand for it.
Sigma-PC | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZEMAX | OSLO | CODE-V | MODAS | ATMOS | WinLens | ACCOS | Sigma2000 | |||||||||
imp. | exp. | imp. | exp. | imp. | exp. | imp. | exp. | imp. | exp. | imp. | exp. | imp. | exp. | imp. | exp. | |
System Definition: | ||||||||||||||||
System Aperture (F-number, num. aperture, ...) | 6 | 6 | 6 | 6 | ||||||||||||
Apodization | NA | NA | NA | NA | NA | NA | ||||||||||
Fields (angle, object / image height) | 7 | 7 | 7 | 7 | ||||||||||||
Field weights | NA | NA | NA | NA | NA | NA | ||||||||||
Wavelengths | 9 | |||||||||||||||
Wavelength weight | NA | NA | NA | NA | ||||||||||||
Reference wavelength | NA | NA | NA | NA | NA | NA | ||||||||||
System notes | 1 | 1 | ||||||||||||||
Surfaces | ||||||||||||||||
Sphere | ||||||||||||||||
Asphere + Toric | 8 | 8 | 8 | 8 | ||||||||||||
Tilted | 5 | NA | NA | |||||||||||||
Tilt order | NA | NA | NA | NA | ||||||||||||
Decentered | 3 | 3 | NA | NA | ||||||||||||
Pickups (thickness, curv., glass, aperture) | NA | NA | NA | NA | NA | NA | ||||||||||
Grating | NA | NA | NA | NA | NA | NA | ||||||||||
Holograms (2-point) | NA | NA | NA | NA | NA | NA | ||||||||||
Comments, Notes | NA | NA | NA | NA | NA | NA | ||||||||||
Mirrors | ||||||||||||||||
Ideal lens | NA | NA | NA | NA | NA | NA | ||||||||||
Glass catalogue names | ||||||||||||||||
Surface Apertures: | ||||||||||||||||
circular | ||||||||||||||||
rectangular | NA | NA | NA | NA | ||||||||||||
elliptical | NA | NA | NA | NA | NA | NA | ||||||||||
obstruction | NA | NA | NA | NA | ||||||||||||
multiple apertures | NA | NA | NA | NA | NA | NA | ||||||||||
aperture decenter | NA | NA | NA | NA | NA | NA | ||||||||||
Gradient Index: | ||||||||||||||||
LightPath Gradium | NA | NA | NA | NA | NA | NA | ||||||||||
Selfoc | NA | NA | NA | NA | NA | NA | ||||||||||
GLC | NA | NA | NA | NA | NA | NA | ||||||||||
mixed gradient | NA | NA | NA | NA | NA | NA | ||||||||||
Miscellaneous: | ||||||||||||||||
Afocal | 2 | 2 | NA | NA | NA | NA | NA | NA | ||||||||
Telecentric beams | 4 | NA | NA | NA | NA | NA | NA | |||||||||
Solves | NA | NA | NA | NA | ||||||||||||
Special Aperture Pickups | NA | NA | NA | NA | NA | NA | ||||||||||
Zoom / Multiconfiguration | NA | NA | NA | NA | 10 |
Zemax Optical Design Software
Zemax Optical Design software, free download Windows 7
Notes:Zemax Software
1 | Only the lens system title is converted (TIT command). |
2 | Since ZEMAX does not offer an 'afocal' mode, an ideal lens is added to the exported system. On import, the ideal lens is recognized and maintained. |
3 | Z-decenter are not supported by ZEMAX. A dummy surface is inserted to simulate Z-decenter. |
4 | Two additional surfaces are added on export to ZEMAX to approximate telecentric beams. |
5 | An additional 'coordinate break' surface is added on export to ZEMAX to exactly model tilted surfaces. |
6 | ATMOS and MODAS only recognize entrance pupil diameter, as defined by the first surface. |
7 | ATMOS and MODAS only support a maximum field angle in object space. |
8 | Toric surfaces are not supported by ATMOS and MODAS. |
9 | WinLens accepts only 5 wavelengths. |
10 | WinLens accepts only 4 zoom positions. |